Rear Door Heat Exchanger (RDHx), CoolDoor 30/50 kW

Delta CoolDoor is the ideal solution for high-power-density racks. With EC fans ensuring reliability and efficiency, it removes heat at the source, preventing hot air in the room. No need for added footprint or raised floor, the CoolDoor saves space and reduces CAPEX. The turbo boost dissipates heat from neighboring racks, and the leakage detection ensures high reliability. Elevate your data center performance with Delta CoolDoor!
Rear Door Heat Exchanger (RDHx), CoolDoor 30/50 kW Complete System
 

Product available regions :

EMEA North America South America SEA India China Taiwan South Korea Japan
       

For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.


Downloads Request a Quote Subscribe Newsletter

Product Introduction

Features & Benefits

Unparalleled Reliability

  • Built-in MCU precisely controls water and air flow for accurate temperature management
  • Ensures chiller system stability during power recovery with a two-way ball valve design post-emergency shutdown
  • Turbo boost control ensures uninterrupted operation by utilizing adjacent RDHx during ball valve or fan failure
  • Enhances equipment protection with 4m water leakage detection and integrated cut-off valve (option) to minimize potential damage
  • Integrated ATS (optional) for continuous operation
  • Elevates security with lockable access door
 

Efficient Use of Space and Energy

  • No hot aisle containment needed
  • Low profile design mounts seamlessly on the rear of the rack, saving valuable space
  • Enhance energy savings with an adjustable fan speed (30-100%) and high-efficiency EC fan
 

Easy Management

  • LCD screen and LED indicators for onsite monitoring system status and control
  • Empowers remote monitoring through input dry contact and external RTU device
  • Tailor-made ducts, perfect for all rack types
  • Hot-swappable fans and sensors allow for quick and easy maintenance
  • Flow control valve (optional) delivers high cooling availability and control
Specifications
  1. Model: D30 / D50 

  2. Cooling Capacity:
    D30: 30 kW(1)
    D50: 50 kW(2)
  3. Rated Air Flow:
    D30: 3812 CFM
    D50: 4016 CFM

  4. Power Supply
  5. Nominal Voltage: 200-240 Vac, 1P2W+PE
  6. Frequency: 50/60 ± 3 Hz
  7. Input Connection Type: NEMA 6-15P, Top inlet

  8. Mechanical
  9. Valve Type: 2-way valve, FC type
  10. Fan Type: EC
  11. Fan Quantity: 4 
  12. Water Leakage Detector: 4m length

  13. Deployment
  14. Rated Power Consumption (Rating Input Power):
    D30: 0.44 kW
    D50: 0.67 kW
  15. Rated Water Flow:
    D30: 55 LPM
    D50: 90 LPM
  16. Piping Connection: Top/ Bottom
  17. Piping Size:
    D30: 1 inch
    D50: 1 1/4 inch

  18. Communication Interface
  19. Display: LCD display with LED indicators
  20. Port: MODBUS (RS-485), Remote On/Off input dry contact, Fire alarm input dry contact, Total alarm output dry contact

  21. Physical
  22. Dimensions (W x D x H): 600 x 345 x 1970 mm 
  23. Net Weight:
    D30: 90 kg    
    D50: 98 kg
  24. Compatible Rack - Height: 2000/ 2200 mm
  25. Compatible Rack - Width: 600/ 800 mm

  26. Environment
  27. Inlet Chiller Water Temperature:
    12 °C (recommended) to 20 °C(3) 
    Inlet chiller water temperature should be higher than dew point temperature
  28. Maximum Operating Pressure: 10 bar (145 psi)
  29. Maximum CW Flow Rate:
    D30: 82 LPM (PICV 69 LPM)
    D50: 122 LPM (PICV 108 LPM)

  30. Conformance
  31. Safety: CE, UL(4)

  32. Features
  33. Leak Detection: Standard
  34. Dual Power Feed/ ATS: Option
  35. PICV Valve: Option
  36. T/RH Sensor-Cold Side Dew Point Monitoring: Option
  37. Cut-off Valve (Isolate Leakage RDHx): Option
  38. Air Static Pressure Sensor: Option
  39. Quick Disconnect Couplings: Option
  40. BACnet: Option
  41. SNMP Card: Option

  42. (1) Conditions for D30 rated capacity at return air: 42 °C, Inlet water 12 °C and outlet water 20 °C
    (2) Conditions for D50 rated capacity at return air: 50 °C, Inlet water 12 °C and outlet water 20 °C
    (3) Over 12 °C requires cooling capacity derating
    (4) UL provided upon request
  43. All specifications are subject to change without prior notice.


Downloads Request a Quote Subscribe Newsletter